F3SJ-B
- Livraria CAD
- F3SJ Safety Light Curtain Datasheet
Thank you for downloading the F3SJ Safety Light Curtain Datasheet
Download againDid you know that 4 out of 5 distributors buy this product in a bundle?
There are many variations of passages of Lorem Ipsum available, but the majority have suffered alteration in some form, by injected humour, or randomised words which don't look even slightly believable.

Modelo básico combinando desempenho e funcionalidade
A família F3SJ-B inclui barreiras de segurança de tipo 4 com resolução óptica de 25 mm. Permite um alcance de funcionamento até 7 m e uma altura de protecção até 2.065 mm sem zona morta.
- Altura de detecção = altura do sensor
- Protecção de mãos simples
- Função de muting disponível
- Ligação em série até três conjuntos
- Sensor Cat. 4 em conformidade com a norma EN 61496-1 e até PLe de acordo com EN ISO 13849
Ordering information
Protective height (mm)1 |
||
---|---|---|
Accessories (sold separately)
Single-end connector cable (2 cables per set, for emitter and receiver)
For wiring with safety circuit such as single safety relay, safety relay unit, and safety controller.
![]() |
|||
Sensor mounting bracket
![]() |
||||
![]() |
||||
![]() |
F39-LJB3-M61 |
|||
F39-LJB3-M82 |
||||
![]() |
Bracket to mount an intermediate bracket to the aluminum frame |
F39-LJB3-M6K1 |
||
F39-LJB3-M8K2 |
||||
![]() |
Mounting bracket used when replacing existing area sensors |
|||
![]() |
Laser pointer
![]() |
Specifications
Setting tool connection4 |
|||
Operating range5 |
|||
15 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets) |
|||
70 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets) |
|||
Emitter: Up to 22 beams: 52 mA max., 26 to 42 beams: 68 mA max., 46 to 62 beams: 75 mA max., 66 to 82 beams: 88 mA max., 86 to 102 beams: 101 mA max. Receiver: Up to 22 beams: 45 mA max., 26 to 42 beams: 50 mA max., 46 to 62 beams: 56 mA max., |
|||
Based on IEC 61496-2. Within ±2.5° for both emitter and receiver when the detection distance is 3 m or over |
|||
Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), Leakage current 1 mA max., load inductance 2.2 H max.6, Maximum capacity load 1 μF7 |
|||
One PNP transistor outputs, load current 100 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), leak current 1 mA max. |
|||
Safety output: On when receiving light |
|||
ON voltage: Vs-3 V to Vs, OFF voltage: 0 V to 1/2 Vs or open8 |
|||
Mutual interference prevention algorithm prevents interference in up to 3 sets. |
|||
Time division emission by series connection Number of connections: up to 3 sets (between F3SJ-Bs only)Other models cannot be connected. |
|||
Output short-circuit protection, and power supply reverse polarity protection |
|||
Operating: 35% to 85% (no condensation), Storage: 35% to 95% RH |
|||
Malfunction: 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps in X, Y, and Z directions |
|||
Malfunction: 100 m/s2, 1,000 times each in X, Y, and Z directions |
|||
Connection method: Prewired connector cable, cable length 0.3 m, connector type (M12, 8-pin), connector: IP67 rated (when mated) |
|||
Test rod, Instruction manual, User's manual (CD-ROM)9 |
|||
IEC 61496-1, EN 61496-1 UL 61496-1, Type 4 ESPE (Electro-sensitive protective equipment) IEC 61496-2, CLC/TS 61496-2, UL 61496-2, Type 4 AOPD (Active opto-electronic protective devices) IEC 61508-1 to -3, EN 61508-1 to -3 SIL3 |
Connections
Basic Wiring Diagram
Wiring when using manual reset mode, external device monitoring (F3SJ-B ____ P25) (PNP output)

6. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the safety output at 4 Hz or less, the usable load inductance becomes larger.
6. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the safety output at 4 Hz or less, the usable load inductance becomes larger.
Catálogos
Mostrar tudo catálogosSubscrever-se na informação especializada
Newsletters acerca das inovações de produtos, soluções e serviços, directamente na suo inbox.
Obrigados por sua incrição a eNews da Omron. Receberá uma mensagem de confirmação com instruções para activar a inscrição. Os seus dados serão mantidos com total confidencialidade.
Temos experienciado dificuldades técnicas. O seu pedido não foi submetido com sucesso. Por favor aceite as nossas desculpas e tente novamente mais tarde. Detalhes: [details]
DownloadDocumentação do produto
Transfira datasheets, manuais e brochuras.
Procurar no centro de transferênciasCursos de formação
Obter a formação dada pelos nossos melhores engenheiros. Nível básico ao avançado.
Ver cursos de formação