U1000
Inversor regenerative Matrix
Classificações: Trifásico, classe de 200 V: 28 A a 248 A; Trifásico, classe de 400 V: 11 A a 414 A
- Operação 4Q com poupança de energia
- Ajuste automático dos dados do motor
- Conversão directa AC-AC altamente eficiente
- Instalação simples e manutenção mínima
- Segurança em conformidade com a função SIL3 STO
- Filtro EMC, corrente harmónica de entrada baixa (THDi < 5%), conversor regenerativo e variador de frequência, tudo em um
- Opções de comunicação: EtherCAT, EtherNet/IP, PROFINET, DeviceNet, PROFIBUS-DP, Modbus TCP/IP, CANopen, MECHATROLINK-II e POWERLINK
- CE, UL, cUL e TÜV
Especificações e info encomendas
Ordering information

Note: U1000 includes EMC filter, input AC reactor, regenerative converter and frequency inverter.
U1000 inverter
Note: The U1000 model has an IP00 protection class. For the IP20 protection class, install the IP20/Nema1 kit.
① Output AC reactor
Note: This table corresponds with HD rating. When ND is used, please choose the reactor for the next size inverter.
① Choke
② Communication option board
③ Accessories
Provides a simple way of installing the LCD |
|||
USB converter for PC tool usage and copy unit for easy parameter setup duplication and backup in one |
④ Input/Output option board
⑤ Feedback speed option board
Specifications
200 V class
Input current at HD1 |
||||||||||||
Input current at ND1 |
||||||||||||
Rated input capacity at HD2 |
||||||||||||
Rated input capacity at ND2 |
||||||||||||
Rated output current at HD3 |
||||||||||||
Rated output current at ND3 |
||||||||||||
HD rating: 150% of rated output current for 60 s ND rating: 120% of rated output current for 60 s (Derating may be required for applications that start and stop frequently) |
||||||||||||
Carrier frequency4 |
4 KHz (user adjustable up to 10 KHz. Derating may be required) |
|||||||||||
400 Hz5 |
||||||||||||
Harmonics current distortion, THDI6 |
||||||||||||
Input power factor6 |
||||||||||||
400 V class
Input current at HD7 |
||||||||||||||||||||
Input current at ND1 |
||||||||||||||||||||
Rated input capacity at HD8 |
||||||||||||||||||||
Rated input capacity at ND2 |
||||||||||||||||||||
Rated output current at HD9 |
||||||||||||||||||||
Rated output current at ND3 |
||||||||||||||||||||
HD rating: 150% of rated output current for 60 s ND rating: 120% of rated output current for 60 s (Derating may be required for applications that start and stop frequently) |
||||||||||||||||||||
Carrier frequency10 |
4 KHz (user adjustable up to 10 KHz. Derating may be required) |
|||||||||||||||||||
400 Hz11 |
||||||||||||||||||||
Harmonics current distortion, THDI12 |
||||||||||||||||||||
Input power factor6 |
||||||||||||||||||||
Dimensions
![]() |
||||||||
IP20/Nema113 |
||||||||
IP20/Nema11 |
||||||||
1. Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring connections and power supply impedance.
3. The rated output current of the drive output amps should be equal to or greater than the motor rated current.
4. Carrier frequency is set to 4 KHz. Current derating is required in order to raise the carrier frequency.
6. If one of the following specifications are needed, the maximum output voltage will be the equivalent to the input voltage × 0.87: Harmonic current distortion of 5% or less, Harmonic suppression guidelines compliance or Input power factor of 0.98 or more.
7. Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring connections and power supply impedance.
9. The rated output current of the drive output amps should be equal to or greater than the motor rated current.
10. Carrier frequency is set to 4 KHz. Current derating is required in order to raise the carrier frequency.
1. Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring connections and power supply impedance.
3. The rated output current of the drive output amps should be equal to or greater than the motor rated current.
4. Carrier frequency is set to 4 KHz. Current derating is required in order to raise the carrier frequency.
6. If one of the following specifications are needed, the maximum output voltage will be the equivalent to the input voltage × 0.87: Harmonic current distortion of 5% or less, Harmonic suppression guidelines compliance or Input power factor of 0.98 or more.
7. Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring connections and power supply impedance.
9. The rated output current of the drive output amps should be equal to or greater than the motor rated current.
10. Carrier frequency is set to 4 KHz. Current derating is required in order to raise the carrier frequency.
Acessórios
Regenerative accessories

DC Supply with Regenerative Active Front End system

Regenerative DC bus supply
Max. input current A1 |
||||||||||
Low harmonic filter
IRMS current A2 |
|||||||||
Heat loss W1 |
|||||||||
Regenerative Braking unit system

Regenerative Braking unit for Low Duty applications (50%)
20 |
||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. current A3 |
||||||||||||||||
Regenerative Braking unit for High Duty applications
Max. current A4 |
|||||||||||
Como o podemos ajudar?
Se tiver alguma questão ou pretender solicitar um orçamento, contacte-nos ou envie um pedido.
Contactar U1000

Obrigado por ter feito o seu pedido. Entraremos em contacto consigo logo que possível.
Temos experienciado dificuldades técnicas. O seu pedido não foi submetido com sucesso. Por favor aceite as nossas desculpas e tente novamente mais tarde. Detalhes: [details]
DownloadOrçamento para U1000
Através deste formulário pode pedir um orçamento para o produto que escolheu. Por favor complete os campos marcados com *. Os seus dados serão tratados confidencialmente.

Obrigado por ter pedido uma cotação. Enviaremos a respectiva informação logo que possível.
Temos experienciado dificuldades técnicas. O seu pedido não foi submetido com sucesso. Por favor aceite as nossas desculpas e tente novamente mais tarde. Detalhes: [details]
Download