G7S

Características

Relés com contactos de guia forçada

A família de relés estreitos G7S-_-E com contactos de guia forçada está disponível numa versão de seis pólos com duas combinações de contactos. Os terminais estão dispostos para facilitar a montagem PCB. É possível soldar directamente num PCB ou utilizar as bases P7SA.
  • Contactos de guia forçada
  • Em conformidade com a EN 50205
  • Contactos NA 10 A a 250 VAC e 10 A a 30 VDC Contactos NF: 6 A a 250 VAC e 6 A a 30 VDC (para cargas resistivas)
  • Isolamento reforçado entre entradas, saídas e pólos
  • Disponíveis relés de 4 e 6 pólos
Especificações e info encomendas

Ordering information

Relays with forcibly guided contacts

Type

Sealing

Poles

Contacts

Rated voltage

Order code

Standard

Flux-tight

6 poles

4PST-NO, DPST-NC

24 VDC

G7S-4A2B-E

3PST-NO, 3PST-NC

G7S-3A3B-E

Sockets

Type

LED indicator

Rated voltage

Order code

Track-mounting

Track mounting and screw mounting
possible

Yes

24 VDC

P7S-14F-END

Back-mounting

PCB terminals

No

-

P7S-14P-E

Specifications

Ratings

Coil

Rated voltage

Rated current (mA)1

Coil resistance (Ω)1

Max. voltage (V)2

Power consumption (W)

24 VDC

30

800

110%

Approx. 0.8

Contacts

Item

Resistive load

Rated load

NO contact

10 A at 250 VAC, 10 A at 30 VDC

NC contact

6 A at 250 VAC, 6 A at 30 VDC

Rated carry current

NO contact

10 A

NC contact

6 A

 

Item

Resistive load

Maximum switching voltage

250 VAC, 30 VDC

Maximum switching current

NO contact

10 A

NC contact

6 A

G7S-_-E Characteristics of Sockets

Model

P7S-14F-END

P7S-14P-E

Continuous current

10 A

Dielectric strength

2000 VAC for 1 min. between terminals

Insulation resistance

1000 MΩ min. 3

Ambient operating humidity

25 to 85%

5 to 85%

Characteristics

Contact resistance4

100 mΩ max.

Operating time5

50 ms max.

Release time2

50 ms max.

Maximum operating frequency

Mechanical

18,000 operations/h

Rated load

1,800 operations/h

Insulation resistance

100 MΩ min.

Durability6

Mechanical

10,000,000 operations min. (at approx. 18,000 operations/h)

Electrical

100,000 operations min. (at the rated load and approx. 1,800 operations/h)

Inductive load switching capability7 (IEC60947-5-1)

NO Contact

AC15 AC240V 5A, DC13 DC24V 2A

NC Contact

AC15 AC240V 3A, DC13 DC24V 2A

Ambient operating temperature

-25 to 70°C (with no icing or condensation)

Ambient operating humidity

5% to 85%

Note: The values listed above are initial values.

 

Please check Omron in the Internet for updated information on product reliability data and the SISTEMA libraries: http://industrial.omron.eu/safety


1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±15%.

2. The maximum voltage is based on an ambient operating temperature of 23°C maximum.

3. Measurement conditions: Measurement of the same points as for the dielectric strength at 500 VDC.

4. Measurement conditions: 5 VDC, 10 mA, voltage drop method.

5. Measurement conditions: Rated voltage operation, ambient operating temperature: 23°C, contact bounce time is not included.

6. The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of 25% to 75%.

7. AC15: cos φ = 0.3, DC13: L/R = 96-ms

1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±15%.

2. The maximum voltage is based on an ambient operating temperature of 23°C maximum.

3. Measurement conditions: Measurement of the same points as for the dielectric strength at 500 VDC.

4. Measurement conditions: 5 VDC, 10 mA, voltage drop method.

5. Measurement conditions: Rated voltage operation, ambient operating temperature: 23°C, contact bounce time is not included.

6. The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of 25% to 75%.

7. AC15: cos φ = 0.3, DC13: L/R = 96-ms

Tem alguma questão?

Estamos sempre à sua disposição.

Contacte-nos

Subscrever-se na informação especializada

Newsletters acerca das inovações de produtos, soluções e serviços, directamente na suo inbox.

Obrigados por sua incrição a eNews da Omron. Receberá uma mensagem de confirmação com instruções para activar a inscrição. Os seus dados serão mantidos com total confidencialidade.

Temos experienciado dificuldades técnicas. O seu pedido não foi submetido com sucesso. Por favor aceite as nossas desculpas e tente novamente mais tarde. Detalhes: [details]

Download

Documentação do produto

Transfira datasheets, manuais e brochuras.

Procurar no centro de transferências

Cursos de formação

Obter a formação dada pelos nossos melhores engenheiros. Nível básico ao avançado.

Ver cursos de formação